Corporate IPS Inverter & Battery Service

Digital wave-form audits, deep-cycle battery discharge diagnostics, and ATS repairs optimized for corporate offices.

Back to Services

Ensuring Zero Interruption for Office Operations

Modern corporate environments are heavily dependent on server closets, network switches, and computer workstations. A slow transfer delay or a distorted wave-form can trigger immediate data losses and hardware failures. The **Maxon IPS Inverter & Battery Service** program keeps your office grid operating with clean, pure sine wave stability.

Our engineering team has extensive experience calibrating high-frequency inverters and managing corporate battery banks. We verify charging cutoffs, service internal transfer relays, analyze wave-forms, and inspect battery charge distributions. This thorough, scientific approach stops unexpected workstation resets and extends battery string life cycles by up to 50%.

ATS Calibrations

Workstation-safe transition delays.

Wave-form Tuning

Pure sine output < 2% THD.

Battery Balancing

Intelligent 3-stage charge controls.

Corporate Support

Priority Office SLAs

Stocked with genuine replacement electronics boards and high-capacity battery units. Directly serving commercial hubs across Dhaka.

  • Corporate SLA Response: < 6 Hours
  • Support: Corporate 1KVA - 30KVA Systems
  • Battery Types: Gel, Tubular, AGM
Call Corporate Desk
Intelligent Audits

Our Inverter & Battery Maintenance Protocol

We apply diagnostic procedures to ensure that your corporate backup systems are completely stable, safe, and ready to take the load during utility cuts.

01

Pure Sine Wave Profiling

Inspecting inverter output wave-forms using digital storage oscilloscopes. We analyze and tune the pulse-width modulation (PWM) logic to ensure total harmonic distortion (THD) remains under 2%, preventing buzzing and overheating in computer power supplies.

Tuned using:Tektronix Handheld OscilloscopesTrue-RMS Clamp Meters
02

Controlled Battery Discharge Cycle

Executing controlled constant-current capacity audits on your tubular and GEL battery banks. This enables our field engineers to calculate actual amp-hour retention vs the original nominal factory curve, identifying failing cells early.

Tuned using:Intelligent DC Load TestersDigital Hydrometers
03

ATS Contact point Refurbishing

Cleaning, adjusting, and polishing the silver-alloy contact points on the internal Automatic Transfer Switch (ATS) relays. This minimizes contact resistance and guarantees transfer delays remain safely under 10ms to prevent workstation resets.

Tuned using:High-Conductivity Oxide CleanersRelay Spring Calibrators
04

Charging Controller Calibration

Calibrating the battery charger board. We set precise constant-current bulk charge caps, float voltage parameters, and temperature-compensated limits to maximize battery lifespan and eliminate the risk of acid outgassing.

Tuned using:Precision DC Voltmeter CalibratorsThermal Sensor Probes
Office Protection

Corporate Case Scenarios

Understanding the precise impact of power drops across various corporate sectors.

Corporate Workstations & Servers

Critical Threat

A sudden utility blackout with a slow transfer switch causes immediate corporate workstation shut downs, interrupting ongoing tasks, corrupting local files, and stressing RAID storage systems.

Maxon Shield

Computer-grade IPS systems calibrated with ultra-fast solid-state ATS switches to guarantee transfer times under 8ms.

Financial & Branch Networks

Critical Threat

Banks and branch offices require continuous operations for POS devices, CCTV monitoring arrays, and central communications routers during high load shedding.

Maxon Shield

Heavy-duty pure sine wave corporate systems with advanced gel battery strings designed for cyclic load operations.

Commercial Retail Hubs

Critical Threat

Sudden darkness in shopping complexes and retail showrooms disrupts customers, invites security threats, and halts critical transaction processing counters.

Maxon Shield

Integrated commercial IPS arrays configured with automatic zone lighting logic and high-amp charging stages.

IPS Failure Signals

If your corporate facilities team logs any of these warning signs, schedule a priority preventative site audit to prevent sudden office outages.

Workstations Resetting on Blackouts

Probable Cause

Deteriorated internal relay response speeds or carbon buildup on the ATS transfer switch contacts, increasing switch time beyond 15ms.

Recommended Response

Urgent transfer relay contact overhaul or complete high-speed ATS board swap.

Drastic Runtimes Reduction

Probable Cause

Sulphation on the internal lead plates, dry battery electrolyte chambers, or a single failing battery cell ruining the entire high-voltage loop.

Recommended Response

De-sulphation restorative charging, cell balancing, or targeted block replacements.

Loud Hum/Whine During Charging

Probable Cause

Loose inductive windings in the transformer core or failing filter capacitors on the central battery charger control loop.

Recommended Response

Charger electronics review and magnetic transformer varnishing/tightening.

Technical Details

IPS Service Performance Parameters

We check and test dynamic inverter and charge states against corporate-grade safety limits.

Operational ParameterStandard Inverter Limit
Inverter Output Wave-formPure Sine Wave Audited (THD < 2.0%)
Transfer Transition Delay< 10 milliseconds (Computer-grade ATS relays)
Supported Battery ChemistriesTubular Lead-Acid, Sealed GEL, Deep-cycle AGM
Charger Circuit ControlIntelligent 3-Stage Smart Charging (Bulk/Float/Equalize)
Input Voltage Acceptance Window140V - 275V AC (Without using battery reserve)
Total Overload Trip Cap110% load for 5 minutes, 150% load for 10 seconds
Inverter Full-Load EfficiencyUp to 88% continuous operation efficiency
Thermal Safety ControlAuto-variable cooling fan, thermal shutdown at 75°C
Support Matrix

Corporate IPS SLA Support Plans

Preventative maintenance agreements tailored for multi-site corporate networks and high-density hubs.

Corporate Standard SLA

Designed for small commercial offices and individual branch backup networks.

Response SLA:< 12 Hours
Audits:Bi-Annual Checkups
OEM Parts:10% Discount on OEM parts
Emergency Hotline:Business hours dispatch
SLA Scope Tasks:
  • Physical structural checks
  • Liquid electrolyte level top-ups
  • ATS transfer response verification
  • Manual load transition test
Recommended SLA

Enterprise Business SLA

Recommended for central corporate offices and heavy retail hubs.

Response SLA:< 6 Hours Guaranteed
Audits:Quarterly Audits (4 times/year)
OEM Parts:20% Discount on OEM parts
Emergency Hotline:24/7 Priority Emergency Hotline
SLA Scope Tasks:
  • All Standard Tier deliverables
  • Pure sine wave harmonic distortion analysis
  • Controlled dynamic battery discharge tests
  • Charging profile board re-calibration
  • Detailed health diagnostic log files

Multi-Site Premier SLA

Bespoke SLA for commercial tower complexes and large corporate branch networks.

Response SLA:< 3 Hours (Dhaka Metropolitan)
Audits:Monthly preventative audits
OEM Parts:All consumable items included
Emergency Hotline:Dedicated engineering team assigned
SLA Scope Tasks:
  • All Enterprise Tier deliverables
  • Immediate standby replacement units
  • Annual battery capacity performance mapping
  • Direct direct corporate support contacts
  • Consolidated multi-site status portals

Request a Corporate Network SLA Audit

Do you manage a multi-site commercial chain or a corporate headquarters tower in Dhaka? Speak with our engineering leads to design a custom preventative support plan.